Description: Optional Feeder Configuration Failure An unsupported Optional Feeder configuration was detected. In multiple feeder configurations, isolate the affected component by removing individual feeders from the system until the error clears. • 72-215-00 Optional feeder configuration failure • 372.215.01 Optional feeder configuration failure
Remedy: 1 Cycle system power. Does the error persist? Go to Step 2. Complete 2 Compare feeder configuration with these allowed configurations. • 550 Sheet Feeder (x1) • 550 Sheet Feeder (x2) • 1100 Sheet Feeder (x1) • 550 Sheet (x1) + 1100 Sheet (x1) • 550 Sheet (x2) + 1100 Sheet (x1) Is the configuration supported? Go to Step 3. Reconfigure the system to a supported configuration. 3 Check PJ21 on the MCU Board and PJ181 and PJ350 on the Feeder Board. The connections are secure. Go to Step 4. Correct the installation. 4 Check continuity of the Upper Option Harness between P/J181 and P/J350 on the Feeder Board. The harness is undamaged. Go to Step 5. Replace the harness. 5 Check continuity of the Harness Assy LPP/ MOT between P/J181 and P/J21 on the MCU Board. The harness is undamaged. Go to Step 6. Replace the harness. 6 Replace the Feeder Board. Does the error persist? Replace the MCU Board. Complete.