Description: Optional Feeder Failure - Feed Drive Motor A failure in the Feed Drive motor of an attached Optional Feeder was detected. Use the error code to isolate the affected component. • 77-216-00 Feeder Motor Failure
Remedy: 1 Test the Feed Drive for the indicated tray using dc330: • Tray 3 (73-011) • Tray 4 (74-003) • Tray 5 (75-003) • Tray 6 (76-003) The motor rotates (On/Off). Go to Step 8. Go to Step 2. 2 Check P/J355 on the Feeder Board and P/J357 on the Feed Drive motor. The connections are secure. Go to Step 3. Secure the connection. 3 Check for 24V at P/J355-2 and -4 on the Feeder Board. Is 24 V available at P/J355-2 and -4 when the Interlock Switch is closed? Replace the Feed Drive. Go to Step 4. 4 Check for 24V at P/J350-10, -11, -12 on the Feeder Board. Is 24V available at P/J350-10, -11, - 12 when the Interlock Switch is closed? Replace the Feeder Board. Go to Step 5. 5 Check continuity of the Upper Option harness. The harness is undamaged. Go to Step 6. Replace the harness. 6 Check for 24V at P/J307-3, -4, -5, -6 on the LVPS. Is 24V available at P/J308 when the Front Interlock Switch is closed? Go to Step 7. Replace the LVPS. 7 Check continuity of the LVPS Harness between P/J308 and PJ24 on the MCU Board. The harness in undamaged. Replace the MCU Board. Replace the harness. 8 Print a test print. Does the error persist? Replace the Feeder Board. Complete.