Description: Density Sensor Failure - ADC Sensor An error was detected in the Front or Rear ADC sensor located in the Procon Assembly. • 92-310-00 Density Sensor Failure
Remedy: 1 Check P/J17 on the MCU Board and P/J108 on the Procon Assy. The connections are secure. Go to Step 2. Secure the connection. 2 Check continuity of the Erase/Exit Harness between P/J108 and PJ17 on the MCU Board. The harness in undamaged. Go to Step 3. Replace the harness. 3 Check for 5V at P/J17-9 and -14 on the MCU Board. Is 5V available at P/J17-9 and -14 when the Front Interlock Switch is closed? Replace the Procon Assy. Go to Step 4. 4 Check for 5V at P/J24-17 on the MCU Board. Is 5V available at P/J24-17 when the Front Interlock Switch is closed? Replace the MCU Board. Go to Step 5. 5 Check continuity of the LVPS Harness between P/J308 and PJ24 on the MCU Board. The harness in undamaged. Replace the LVPS. Replace the harness. 6 If the error persists, replace these components, in order, until the error is resolved. 1. Procon Assy, PL5.3.1 2.MCU Board, PL10.2.18