Description: Imaging Unit Failure A calibration patch error (low image density) was detected. • 92-670-00 Yellow Imaging Unit Failure • 92-671-00 Magenta Imaging Unit Failure • 92-672-00 Cyan Imaging Unit Failure • 92-673-00 Black Imaging Unit Failure
Causes: • Yellow Imaging Unit, PL5.1.8 • Magenta Imaging Unit, PL5.1.9 • Cyan Imaging Unit, PL5.1.10 • Black Imaging Unit, PL5.1.11 • Transfer Belt, PL5.1.1 • HVPS, PL5.2.3 • Harness Assy ROS/HV (PL11.2.2) • MCU Board, PL10.2.18
Remedy: 1 Reseat the affected Imaging Unit and cycle system power. Does the error persist? Go to Step 2. Complete. 2 Replace the affected imaging Unit. Does the error persist? Go to Step 3. Complete. 3 Reseat the Transfer Belt and cycle system power. Does the error persist? Go to Step 4. Complete. 4 Replace the Transfer Belt. Does the error persist? Go to Step 5. Complete. 5 Check P/J332 on the HVPS and the HV contacts to the Bias Transfer Assy. The connections are secure. Go to Step 6. Secure the connections. 6 Check P/J13 on the MCU Board and P/J331 on the HVPS. The connections are secure. Go to Step 5. Secure the connections. 7 Check continuity of the ROS/HV Harness between P/J331 and PJ31 on the MCU Board. The harness in undamaged. Replace the HVPS. Replace the MCU Board. 8 If the error persists, replace these components, in order, until the error is resolved. 1. Bias Housing Assy, PL 5.2.2 2.HVPS, PL5.2.3 3. Harness Assy ROS/HV (PL11.2.2) 4.MCU Board, PL10.2.18