Mã lỗi 010-311 ... 010-355 — Xerox Phaser 7100

Code: 010-311 ... 010-355

Description: • 010-311: Fuser Unit Heat Roll STS-1 Disconnection Fail • 010-319: Fuser Unit NC Sensor Differential Amp Fail • 010-328: Fuser Unit Warm Up Time Fail (Not Ready) • 010-331: Heat Roll STS Over Temperature Fail • 010-332: Heat Roll NC Sensor Disconnection Fail • 010-333: Heat Roll NC Sensor Over Temperature Fail • 010-334: Heat Roll NC Sensor Broken Fail • 010-335: Heat Roll NC Sensor Range Fail • 010-338: Fuser Unit On Time Fail • 010-339: Heat Roll NC Sensor Low Temperature Fail • 010-340: Fuser Unit Detached • 010-344: Heat Roll STS Sensor Low Temperature Fail • 010-345: Fuser Unit Hard Relay Off Fail • 010-346: Fuser Main Lamp Data Renewal Fail • 010-347: Fuser Sub Lamp Data Renewal Fail • 010-355: Fuser Cool Down Timeout Fail.
Fuser Unit Fail The Fuser Unit has failed due to one of the following problems. • A differential circuit output error was detected between the detection output and the compensation output of the Fuser Unit NC Sensor. • When the Lamp On time meets the following conditions, where Tws °C is the temperature at the Wait state start time that is obtained at the NCSCenter. • The temperature monitor AD value of the STS-Front was detected to be higher than T[HITMP (2)] 3 times in a row. • During Warm Up Control, an abnormal detected temperature due to NC Sensor malfunction or poor contact was detected. • The Fuser Unit Main Lamp or Sub Lamp has been On continuously for longer than the setting time (NVM). • At the first Lamp Off after it was turned On, the NC temperature is continuously at EP_U4_LOW_NC °C or lower 8 or more times in a row. • The Thermistor disconnection detected. • At the first Heater OFF after it was turned On, the detected temperature at the edge STS is continuously at EP_U4_LOW_STS °C or lower 8 or more times in a row. • Notified at the moment the Relay is cut off from the circuit. • The detected temperature at the NC or the STS has not changed during this period, although the Main Lamp has been On continuously for 15 s or longer. • The Cool Down Mode has continued for EP_U4_COOL_TIME * 10 s or longer.
Causes: • DRW Fuser Harness Assembly, PL 4.1.7 • Fuser Unit, PL 10.1.1 • MCU PWB, PL 12.1.15 • AC PWB Assembly, PL 12.1.16 • LVPS PWB, PL 12.2.1 • Option Harness Assembly, PL 12.3.5
Remedy: 1. Check the installation of the Fuser Unit. Is the Drawer Connector between the Fuser Unit and Main Unit (P/J601) free of broken/bent pins, debris, burns, and etc., and the unit is installed properly? Go to step 2. Reinstall the Fuser Unit. 2. Check the connections between the Fuser Unit and MCU PWB, as well as between the Fuser Unit and AC PWB. Are the connectors P/J601, P/J459, and P/J503 connected securely? Go to step 3. Connect the connectors P/J601, P/J459, and P/J503. 3. Check the connection between the AC PWB and MCU PWB. Are the connectors P/J505 and P/J464 connected securely? Go to step 4. Connect the connectors P/J505 and P/J464. 4. Check the conductivity of the DRW Fuser Harness Assembly. Are the connections between P/J601<=> P/J459 and between P/J601 <=> P/J503 conducting properly? Go to step 5. Replace the DRW Fuser Harness Assembly. 5. Check the conductivity of the Option Harness Assembly. Is the connection between P/J505 <=> P/J464 conducting properly? Go to step 6. Replace the Option Harness Assembly. 6. Check the voltage supply (+5VDC) to the Fuser Unit. Measure the voltages between the MCU PWB GND <=> P/J459-5 and MCU PWB GND <=> P/J459-13. Is there a voltage (approx. +5VDC) output? Go to step 7. Go to +5VDC Power Troubleshooting. 7. Check the voltage supply (+3.3VDC) to the Fuser Unit. Measure the voltage between the MCU PWB GND <=> P/J459-1. Is there a voltage (approx. +3.3VDC) output? Go to step 8. Go to +3.3VDC Power Troubleshooting. 8. Replace the Fuser Unit. Does the error persist? Go to step 9. Troubleshooting complete. 9. Replace the AC PWB. Does the error persist? Replace the MCU PWB. Troubleshooting complete.

← Xem tất cả mã lỗi Xerox Phaser 7100

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie