Code: 042-323
Description: (K) Drum Motor Failure The change of the port status at the failure of the Drum Motor is always monitored.
Causes: • Imaging Unit (K), PL 6.1.4 • PR Harness Assembly (K), PL 11.1.23 • PR Drive Assembly Kit, PL 11.1.99 • MCU PWB, PL 12.1.15 • LVPS PWB, PL 12.2.1 • Main Harness Assembly, PL 12.3.1
Remedy: 1. Check the installation state of the Imaging Unit (K)). Is the Imaging Unit (K) installed properly, with no contamination at the contact points and in contact with the left and right guides? Go to step 2. Clean the contact points. Reinstall the Imaging Unit (K). 2. Check the Drum Motor (K) operation. Perform DC330 Component Control [071-005] to check the rotation of the Drum Motor (K). Is the Motor working properly? Replace the MCU PWB. Go to step 3. 3. Check the installation of the Drum Motor (K)). Manually rotate the Drum Motor (K). Does the Motor rotate? Reinstall the Drum Motor (K). Go to step 4. 4. Check the connections between the Drum Motor (K) and MCU PWB, as well as between the Drum Motor (K) and LVPS PWB. Are the connectors P/J472, P/J4723, P/J4724, P/J524, P/J5246, and P/J5243 connected securely? Go to step 5. Re-connect the connectors P/J472, P/J4723, P/J4724, P/J524, P/J5246, and P/J5243. 5. Check the conductivity between the Drum Motor (K) and Relay Connector. Are the connections between P/J4724 <=> P/J4723 and between P/J5243 <=> P/J5246 conducting properly? Go to step 6. Replace the PR Harness Assembly (K). 6. Check the conductivity between the Relay Connector and LVPS PWB. Is the connection between P/J5246 <=> P/J524 conducting properly? Go to step 7. Replace the Main Harness Assembly. 7. Check the conductivity between the Relay Connector and MCU PWB. Is the connection between P/J4723 <=> P/J472 conducting properly? Go to step 8. Replace the Main Harness Assembly. 8. Check the voltage supply (+3.3VDC) to the Drum Motor (K). Measure the voltage between the MCU PWB GND <=> P/J472-16. Is there a voltage (approx. +3.3VDC) output? Go to step 9. Refer to +3.3VDC Power Troubleshooting. 9. Check the voltage supply (+24VDC) to the Drum Motor K. Measure the voltage between LVPS PWB GND <=> P/J524-5. Is there a voltage (approx. +24VDC) output? Close the Interlock Switch and check. Replace the Drum Motor (K)). Replace the LVPS PWB.