Mã lỗi 092-316 — Xerox Phaser 7100

Code: 092-316

Description: Environment (Temp/ Humidity) Sensor Error The Environment (external) Sensor temperature error (low temp/ high temp).
Causes: • MCU PWB, PL 12.1.15 • Temp/ Humidity (Environmental) Sensor, PL 12.2.18 • Main Harness Assembly, PL 12.3.1
Remedy: 1. Check the installation of the Temp/ Humidity (Environmental) Sensor Sensor). Is the Temp/ Humidity Sensor installed properly? Go to step 2. Reinstall the Humidity Sensor. 2. Check the connection between the Temp/ Humidity Sensor and MCU PWB. Are the connectors P/J4651B and P/J465A connected securely? Go to step 3. Connect the connectors P/J4651B and P/J465A. 3. Check the conductivity between the Temp/ Humidity Sensor and MCU PWB. Is the connection between P/J4651B <=> P/J465A conducting properly? Go to step 4. Replace the Main Harness Assembly. 4. Check the voltage supply (+5VDC) to the Temp/ Humidity Sensor. Measure the voltage between the MCU PWB GND <=> P/J465A-B4. Is there a voltage (approx. +5VDC) output? Go to step 5. Go to +5VDC Power Troubleshooting. 5. Replace the Temp/ Humidity Sensor Sensor). Does the error persist? Replace the MCU PWB. Troubleshooting complete.