Remedy: 1. Check the installation of the Waste Cartridge. Is the Waste Cartridge installed properly? Go to step 2. Reinstall the Waste Cartridge. 2. Check the Waste Cartridge Set Switch operation. Perform DC330 Component Control [041-301] to check the operation of the Waste Cartridge Set Switch. Is it working properly? Replace the MCU PWB. Go to step 3. 3. Check the connection between the Waste Cartridge Set Switch and LVPS PWB. Are the connectors P/J5225 and P/J522 connected securely? Go to step 4. Connect the connectors P/J5225 and P/J522. 4. Check the voltage supply (+5VDC) to the Waste Cartridge Set Switch. Measure the voltage between the LVPS PWB GND <=> P/J522-5. Is there a voltage (approx. +5VDC) output? Close the Interlock Switch and check. Replace the Waste Cartridge Set Switch. Replace the LVPS PWB.