Description: ESS NVRAM Data Compare Fail During the Read/Write check at power ON, “ESSNVRAM with default factory settings installed” or “ESS-NVRAM data is incorrect” was detected in the System Cont. At the detection of 116-334, because the ESSNVRAM data has been overwritten by the initialization data in the ESS-ROM, turning the power OFF and ON after that causes mismatches in 3 locations for each type that results in a system fail (124-3xx).
Remedy: 1. Because the mismatch error 124-3xx in 3 locations for each type are expected at the power Off/ On after the detection of 116-334, follow the procedure for the appropriate Fault Code and use the suitable DC132 Machine Serial Number Settings to fix the problem. 2. If the 116-334 persists after turning the power Off and On, remove and reinstall the NVRAM I/P PWB) and turn On the printer power. 3. If the problem still persists, replace the NVRAM I/P PWB). 4. If the problem still persists, replace the I/P PWB PWB). 5. If the 116-334 problem persists, go to Common System Fail.