Code: -06
Description: Close Top Cover
Remedy: 1 Cycle power to the printer and open and close the top cover. Does the error still appear? Go to step [2]. Complete 2 Use service diagnostics to test the top cover interlock switch. Does the switch operate correctly? Go to step [3]. Go to step [5]. 3 Visually inspect the switch for defects, damage or possible debris which could prevent the printer for recognizing the top cover is closed. Is the switch free from defects? Go to step [4]. Clean or replace the Top Cover Interlock Switch. 4 Check to see if the Top Cover actuator, located on the Top Cover Inner frame, is broken or damaged. Is the actuator damaged or broken? Replace the Top Cover Inner Frame. Replace the Engine Controller Board. 5 Close the top cover and verify +34 volts on the Engine Controller Board at the COVOPEN Pin 1. Go to step [6]. Go to step [7]. 6 Check for +34 volts on the Engine Controller Board at the COVOPEN Pin 3. Replace the Engine Controller Board. Replace the Top Cover Interlock Switch. 7 Verify the Low Voltage Power Supply to the Power connector on the Engine Controller Board is supplying +34 volts to pins 12, 13, and 14. Replace the Engine Controller Board. Replace the Low Voltage Power Supply and/or wiring harness.