Mã lỗi A6, A7, A10, A22 — Xerox Phaser 7300

Code: A6, A7, A10, A22

Description: Jam at Top Cover A6: Jam at the MPT or under Imaging Units. A7: Jam at Fuser Exit. A10: Jam at output area. A22: Jam in the paper feed path, including under the Imaging Units.
Remedy: 1 Ensure the correct weight and type of paper is loaded in the tray. See “Media and Tray Specifications” on page 1-16 for approved media types and weights. Go to step [2]. Load approved media and run a set of test prints through the printer. If a jam still occurs, go to step [2]. 2 Check the Registration Rollers and Transfer Unit for any spilled toner or obstructions. Clean and remove any obstruction in the paper path. Complete Go to step [3]. 3 Check the fuser for fuser wrap, debris or contamination. Remove the Fuser covers and ensure the thermistors are not broken or dislodged. Replace the Fuser. Go to step [4]. 4 Check the following rollers for excessive wear, and clean to free from dirt or debris: MPT Pick Rollers Eject Guide Assembly Rollers Fuser Rollers Exit Rollers Feeder Assembly Rollers Registration Rollers and grounding strap Did this fix the problem? Go to step [5]. Replace the appropriate roller assembly. 5 Inspect the following actuators for damage and use service diagnostics to test the sensor operation: MPT Entrance Sensor Registration Entrance Sensor Fuser Exit Sensor Transfer Unit Entrance Sensor Do the actuators and sensors operate correctly? Go to step [8]. Replace the problem actuator For a problem sensor, go to step [6] 6 Check the sensor for debris that could interfere with normal operation. Is there debris present? Clean the sensor or remove debris. Go to step [7]. 7 Verify the wiring harness for the problem sensor is free from damage or defects. Replace the sensor. Replace the wiring harness. 8 Use service diagnostics to test the following: Exit Gate Solenoid (Duplex) Face-up Solenoid (Top-Side Output) Do the solenoids operate correctly? Go to step [9]. Replace the solenoid. 9 Visually inspect the Registration Rollers for gaps between rollers and ensure the grounding strap is in place properly. Is there a gap between the Registration Rollers? Replace the Registration Roller Assembly. Go to step [10]. 10 Use service diagnostics to test the following motors/clutches. Main Feed Motor Transfer Unit Motor Registration Motor Registration Clutch Fuser Motor Does the motor/clutch function correctly? Replace the Engine Controller Board. Go to step [11]. 11 Inspect the wiring harness for each motor and clutch. Are the wiring harnesses properly connected and free from defects? Replace the Engine Controller Board. Replace the wiring harness and/or the problem motor/clutch.

← Xem tất cả mã lỗi Xerox Phaser 7300

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie