Code: 941, 942
Description: [CM][YK] Toner Supply Failure The Low Toner Sensor indicates a supply failure at the indicated Imaging Unit. Code 941: Toner supply failure with Cyan or Magenta Toner. Code 942: Toner supply failure with Yellow or Black Toner.
Causes: • Toner Cartridges, PL1.1.24 • Imaging Unit, PL1.1.23 • Toner Motors, PL5.1.22 • Imaging Unit Sensor Board, PL5.1.21
Remedy: 1 Check the following for evidence of fault or damage: • Toner Cartridge • Imaging Unit Agitator Bar • Low Toner Sensors Is there any damage, debris or blockage? Replace any damaged parts. Go to Step 2. 2 Test the affected Toner Motor. 1. Remove the CM or YK Toner Cartridges. 2. Run the appropriate Service Diagnostics Toner Supply Motor test. Does the motor rotate? Go to Step 3. Replace the motor. If the error persists, replace the Motor Driver Board. 3 Does the plunger that engages the Agitation Bar move in and out while the Toner Motor rotates? Go to Step 4. Replace the Toner Supply Camshafts. 4 Test the affected Low Toner Sensors. 1. Remove the CM or YK Imaging Units. 2. Run the appropriate Service Diagnostics Toner Cart Sensor test. Do the sensors function correctly? Replace the Engine Control Board Replace the Imaging Unit Sensor Board.