Code: F110
Description: Finisher Staple Motor Failure An error was detected in the Staple Motor.
Causes: • Finisher Staple Motor • Finisher Control Board
Remedy: 1 Test these sensors. • Staple Clock Sensor • Fold Home Position Sensor Run the appropriate Service Diagnostics sensor test. Do the sensors operate? Go to Step 2. Replace the sensor. If the error persists, go to Step 2. 2 Test the Staple Motor. 1. Close the Interlock Switches for test. 2. Run the Service Diagnostics Staple Motor tests. Does the motor operate? Replace the Finisher Control Board. If the error persists, go to Step 4. Go to Step 3. 3 Check for +24 V to the Staple Motor. Disconnect CN71. Is there +24 V across CN71-1 and -2 <=> ground? Replace the Staple Motor. Replace the harness. If the error persists, go to Step 4. 4 Check all pins of the Inverter Interface Cable for continuity. Disconnect CN1 and CN2 from the Finisher Control Board and the opposite end from the Inverter. Is the cable conductive? Replace the Inverter Power Supply. Replace the cable.