Code: F111
Description: Finisher Stack Handling Motor Failure The Delivery Belt Home Position Sensor detected a Stack Handling error.
Causes: • Finisher Stack Handling Motor • Finisher Control Board
Remedy: 1 Check the delivery mechanism. Does the Delivery Belt turn freely when operated manually? Go to Step 2. Repair the mechanism. 2 Test the Delivery Belt Home Position Sensor. Run the Service Diagnostics Exit Belt Home Position Sensor test. Does the sensor operate? Go to Step 3. Replace the sensor. If the error persists, go to Step 3. 3 Test the Staple Motor. 1. Close the Interlock Switches for test. 2. Run the Service Diagnostics Staple Motor tests. Does the motor operate? Replace the Finisher Control Board. If the error persists, go to Step 4. Go to Step 4. 4 Check for +24 V to the Staple Motor. Disconnect CN59. Is there +24 V across CN59-1 and -2 <=> ground? Replace the Stack Handling Motor. Replace the harness. If the error persists, go to Step 5. 5 Check all pins of the Inverter Interface Cable for continuity. Disconnect CN1 and CN2 from the Finisher Control Board and the opposite end from the Inverter. Is the cable conductive? Replace the Inverter Power Supply. Replace the cable.