Code: F115
Description: Finisher Lift Motor Failure The Paper Surface, Upper Limit, or Lift Motor Clock Sensor detected a Lift Motor error.
Causes: • Upper Tray Lift Motor • Finisher Control Board • Inverter Power Supply
Remedy: 1 Test each of these sensors. • Paper Surface Sensor • Tray Upper Limit Sensor • Shift Motor Clock Sensor Run the appropriate Service Diagnostics sensor test. Do all sensors function correctly? Go to Step 2. Replace the sensor. If the error persists, go to Step 2. 2 Check the tray lift mechanism. Does the mechanism move freely? Go to Step 5. Repair the lift mechanism. 3 Test the Lift Motor. 1. Close the Interlock Switches for test. 2. Run the Service Diagnostics Shift Motor test. Does the motor operate? Go to Step 8. Replace the motor. If the error persists, go to Step 6. 4 Check for +24 V to the Lift Motor. Disconnect CN70. Is there +24 V across CN70-1 and -2 <=> ground when the test is executed? Replace the Lift Motor. Replace the Finisher Control Board. If the error persists, go to Step 5. 5 Check all pins of the Inverter Interface Cable for continuity. Disconnect CN1 and CN2 from the Finisher Control Board and the opposite end from the Inverter. Is the cable conductive? Replace the Inverter Power Supply. Replace the cable.