Code: F116
Description: Finisher Exit Failure The Delivery Belt Home Position Sensor detected a Delivery Motor error.
Causes: • Finisher Delivery Motor • Finisher Control Board
Remedy: 1 Test the Exit Motor. 1. Close the Interlock Switches for test. 2. Run the Service Diagnostics Finisher Bundle Motor tests. Does the motor operate? Complete. Go to Step 2. 2 Check for +24 V to the Exit Motor. Disconnect CN59. Is the +24 V across CN59-1 and -2 <=> ground? Replace the Exit Motor. Go to Step 3. 3 Check Finisher Control Board for +24 V. 1. Disconnect CN13 on the Finisher Control Board. Is the +24 V across CN13-1 and -2? Replace the Exit Motor Harness. Replace the Finisher Control Board. If the error persists, go to Step 4. 4 Check the Inverter Interface Cable for continuity. Disconnect CN1 and CN2 from the Finisher Control Board and the opposite end from the Inverter. Is the cable conductive? Replace the Inverter Power Supply. Replace the cable.