Code: F134
Description: Finisher Punch Motor Failure An error was detected in the Punch Motor.
Causes: • Punch Motor • Punch Control Board • Inverter Power Supply
Remedy: 1 Test the Punch Motor. 1. Close the Interlock Switches for test. 2. Run the Service Diagnostics Punch Motor test. Does the motor operate? Complete. Go to Step 2. 2 Check for +24 V to the Punch Motor. Disconnect P/J2002. Is the +24 V across J2002-1 <=> ground? Replace the Punch Motor. Go to Step 3. 3 Check Punch Control Board for 24 V. 1. Disconnect P/J1002 on the Punch Control Board. Is the +24 V across P1002 pins 1 and 2? Replace the Punch Motor Harness. Replace the Punch Control Board. If the error persists, go to Step 4. 4 Check all pins of the Inverter Interface Cable for continuity. Disconnect CN1 and CN2 from the Finisher Control Board and the opposite end from the Inverter. Is the cable conductive? Replace the Inverter Power Supply. If the error persists, replace the Finisher Control Board. Replace the cable.