Description: Finisher Punch Unit Transfer Motor Failure An error was detected in the Punch Transfer Motor.
Causes: • Punch Transfer Motor • Punch Control Board • Inverter Power Supply
Remedy: 1 Test the Punch Transfer Motor. 1. Close the Interlock Switches for test. 2. Run the Service Diagnostics Transfer Motor test. Does the motor operate? Complete. Go to Step 2. 2 Check for +24 V to the Punch Transfer Motor. Disconnect P/J2001. Is the +24 V across J2001-1 <=> ground? Replace the Punch Transfer Motor. Go to Step 3. 3 Check Punch Control Board for 24 V. 1. Disconnect P/J1001 on the Punch Control Board. Is the +24 V across P1001 pins 1 and 2? Replace the Punch Transfer Motor Harness. Replace the Punch Control Board. If the error persists, go to Step 4. 4 Check all pins of the Inverter Interface Cable for continuity. Disconnect CN1 and CN2 from the Finisher Control Board and the opposite end from the Inverter. Is the cable conductive? Replace the Inverter Power Supply. If the error persists, replace the Finisher Control Board. Replace the cable.