Code: FN1
Description: Jam at Finisher Punch Unit Media did not clear the Finisher Entrance Sensor on time. This error represents a jam at the Finisher entrance.
Causes: • Punch Unit • Finisher Entrance Sensor • Finisher Transport Rollers
Remedy: 1 Check the following for evidence of fault or damage: • Punch Unit • Transport Rollers • Exit Rollers Are there any defects or misalignment? Replace any damaged parts. Go to Step 2. 2 Test the Finisher Entrance Sensor. Run the Service Diagnostics Finisher Entrance Sensor test. Does the sensor function correctly? Replace the Engine Control Board. Replace the sensor. If the error persists, go to Step 3. 3 Check the Entrance Sensor signal at the Finisher Control Board. Actuate the Entrance Sensor. Does the voltage across CN16-12 <=> ground change when the sensor is actuated? Replace the Finisher Control Board. Replace the harness.