Code: FN3
Description: Jam at Finisher Door H Media reached the Finisher Entrance Sensor, but did not clear before the arrival of a second sheet. This error represents a multi-sheet jam in the Finisher. Paper remains in the path after another jam in the Finisher has been cleared
Causes: • Punch Unit • Finisher Entrance Sensor • Finisher Inverter Rollers
Remedy: 1 Check the following for evidence of fault or damage: • Inverter • Inverter Rollers • Finisher Transport Rollers Are there any defects or misalignment? Replace any damaged parts. Go to Step 2. 2 Test the Finisher Entrance Sensor. Run the Service Diagnostics Finisher Entrance Sensor test. Does the sensor function correctly? Replace the Engine Control Board. Replace the sensor. If the error persists, go to Step 3. 3 Check the Entrance Sensor signal at the Finisher Control Board. Actuate the Entrance Sensor. Does the voltage across CN16-12 <=> ground change when the sensor is actuated? Replace the Finisher Control Board. Replace the harness.