Mã lỗi T29 — Xerox Phaser 7400

Code: T29

Description: Temp Sensor Failure The Temperature Sensor has failed.
Causes: • Temp/Humidity Sensor, PL8.1.80 • ENV Harness, PL8.1.81 • Engine Control Board, PL1.1.4
Remedy: 1 Test the Temp/Humidity Sensor. 1. Run the Service Diagnostics Ambient Temp/Hum Sensor test. 2. Verify proper operation by blowing on the sensor. Is the sensor operating correctly? Replace the Engine Control Board. Go to Step 2. 2 Replace the Temp/Humidity Sensor. Does the error persist? Go to Step 3. Complete. 3 Check the ENV harness connection. Is the ENV Harness connected? Go to Step 4. Reconnect the harness. 4 Check all pins on the ENV Harness for continuity. 1. Disconnect ENV and P/J420. 2. Check continuity between ENV <=> J420. Go to Step 5. Replace the ENV Harness. 5 Check the Temp/Humidity Sensor signal. Is there voltage present at FSNS-17 when the sensor is active? Go to Step 6. Replace the Front Sensor Board. 6 Check all pins on the FSNS Harness PL4.2.98 for continuity. 1. Disconnect FSNS. 2. Check continuity on all contacts. Replace the Motor Driver Board. Replace the FSNS Harness.