Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi T40 — Xerox Phaser 7400

Code: T40

Description: Transfer Unit Fan Failure
Causes: • Transfer Unit Fan, PL5.1.48 • Motor Driver Board, PL2.1.10
Remedy: 1 Test the Transfer Unit Fan. Run the Service Diagnostics Belt Fan test. Does the Fan operate correctly. Replace the Engine Control Board. Go to Step 2. 2 Check the Fan connection. Is BELTFAN on the Motor Driver Board securely connected? Go to Step 3. Connect the Fan. 3 Check for +24 V at the Fan connector. Disconnect the Fan from BELTFAN. Is there +24 V between BELTFAN-1 <=> ground? Replace the Fan. Go to Step 4. 4 Check for +24 V at the POW24 connector. Disconnect the POW24 Harness from the Motor Driver Board. Is there +24 V between POW24-1 <=> ground? Replace the Motor Driver Board. Go to Step 5. 5 Check continuity of the POW24 Harness. Is the wiring harness conductive? Replace the LVPS Replace the harness.

← Xem tất cả mã lỗi Xerox Phaser 7400