Mã lỗi TC2 — Xerox Phaser 7400

Code: TC2

Description: Jam in Fuser Media reached the Media Slack Sensor, but did not clear the Fuser Exit Sensor on time. This error represents a jam inside the Fuser.
Causes: • Fuser, PL1.1.21 • Fuser Exit Sensor, PL11.1.13 • Rear Sensor Board, PL11.1.33 • Fuser Motor, PL2.1.9 • Motor Driver Board, PL2.1.10
Remedy: 1 Check the following for evidence of fault or damage: • Fuser • Fuser Exit Actuator and Sensor • Fuser Motor Is there any damage? Replace any damaged parts. Go to Step 2. 2 Remove the Fuser and check for broken or bent connector pins or damaged gears. Repair or replace damaged parts. Go to Step 3. 3 Reinstall the Fuser. Does the error persist? Go to Step 4. Complete 4 Test the Fuser Exit Sensor. Run the Service Diagnostics Fuser Exit Sensor Test. Does the sensor function correctly? Go to Step 7. Replace the sensor. If the error persists, go to Step 5. 5 Check all pins on the SNS Harness for continuity. 1. Disconnect SNS from the Rear Sensor Board. 2. Check continuity between SNS<=>J140. Go to Step 6. Replace the SNS Harness. If the error persists, go to Step 6. 6 Check the HEATR signal to the Engine Control Board. 1. Disconnect RSNS from the Rear Sensor Board. 2. Actuate the Fuser Exit Sensor. Does the voltage across RSNS-6 <=> ground change? Replace the Engine Control Board. Replace the Rear Sensor Board. 7 If possible print one sheet of paper. Does the Fuser Motor turn? Inspect and replace defective gear(s). Go to Step 8. 8 Test the Fuser Motor. Run the Service Diagnostics Fuser Motor test. Does the Fuser Motor function correctly? Replace the Fuser. Go to Step 9. 9 Check for +24 V to the Fuser Motor. Disconnect DCHEAT on the Motor Driver Board. Is there +24 V across DCHEAT-3 <=> ground? Go to Step 10. Replace the Motor Driver Board. If the error persists, go to Step 10. 10 Replace the Fuser Motor. Does the Fuser Motor function correctly? Complete Go to Step 11. 11 Check the DRV0 and DRV1 ribbon cables that connect the Motor Driver Board to the Engine Control Board. Are these cables connected and undamaged? Replace the Engine Control Board. Replace the SVM1 and SVM2 Harnesses.

← Xem tất cả mã lỗi Xerox Phaser 7400

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie