Code: TC3
Description: Jam at Duplex Entrance Media reached the Fuser Exit Sensor, but did not reach the Duplex Entrance Sensor on time. This error represents a jam at the Duplex entrance or in the Exit Assembly.
Causes: • Duplex Unit, PL16.1.0 • Duplex Entrance Sensor, PL16.1.4 • Exit Assembly, PL11.1.0 • Fuser Motor, PL2.1.9 • Motor Driver Board, PL2.1.10
Remedy: 1 Check the following for evidence of fault or damage: • Duplex Unit • Exit Gate • Exit Assembly • Duplex Gate Are there any defects? Replace any damaged parts. Go to Step 2. 2 Test the Duplex Entrance Sensor. Run the Service Diagnostics Duplex Entrance (IN1) Sensor test. Does the sensor function correctly? Go to Step 4. Replace the Duplex Entrance Sensor, if the error persists, go to Step 3. 3 Check DUPLEX Harness continuity. Is the DUPLEX Harness conductive? Go to Step 4. Replace the DUPLEX Harness. 4 Print a test print in Duplex mode Does the sheet reverse in the printer? Go to Step 6. Replace the Duplex Unit. If the error persists, go to Step 5. 5 Check for +24 V to the Duplex Motors. Disconnect DUPLEX on the Motor Driver Board. Is there +24 V at DUPLEX-6 <=> ground? Go to Step 6. Go to Step 10. 6 Test the Fuser Motor. Run the Service Diagnostics Fuser Motor test. Does the Fuser Motor function correctly? Go to Step 8. Go to Step 7. 7 Check for +24 V to the Fuser Motor. Disconnect DCHEAT on the Motor Driver Board. Is there +24 V at DCHEAT-3 <=> ground? Replace the Fuser Motor. Go to Step 10. 8 Test the Exit Gate Solenoid. Run the Service Diagnostics Exit Gate Solenoid test. Does the solenoid function correctly. Replace the Exit Assembly. Go to Step 9. 9 Check for +24 V to the solenoid. 1. Actuate the interlock switches. 2. Disconnect SOLENOID from the Rear Sensor Board. Is there +24 V across SOLENOID-1 <=> ground? Replace the solenoid. Replace the Rear Sensor Board. 10 Check Motor Driver Board POW24 connector for 24 V. 1. Disconnect POW24. Is there +24 V across POW24-1 <=> POW24-2? Replace the Motor Driver Board. Go to Step 11. 11 Check for 24 V at the LVPS 1. Disconnect CN2 on the LVPS. Is there +24 V across pins 1 and 2? Replace the POW24 Harness. Replace the LVPS. 12 Check the DRV0 and DRV1 ribbon cables that connect the Motor Driver Board to the Engine Control Board. Are these cables connected and undamaged? Replace the Engine Control Board. Replace the DRV0 and DRV1 Harnesses.