Code: U10
Description: Top Cover Cooling Fan Failure
Causes: • Top Cover Fan, PL12.1.4 • IDFAN Harness, PL5.1.31 • GTG0 Harness, PL5.1.32
Remedy: 1 Test the Top Cover Fan. Run the Service Diagnostics Top Cover Fan test. Does the fan operate correctly. Replace the Engine Control Board. Go to Step 2. 2 Check the Fan connection. Is P/J492 securely connected? Go to Step 3. Connect the Fan. 3 Check continuity of the Top Cover Fan Harness. Is the wiring harness conductive? Replace the Fan. If the error persists, go to Step 4. Replace the harness. 4 Verify +24 volts is available to the Fan. Disconnect IDFAN. Is there +24 volts at IDFAN-??? Go to Step 5. Go to Step 6. 5 Check continuity of the IDFAN Harness. Is the wiring harness conductive? Go to Step 6. Replace the harness. 6 Verify +24 volts is available to the Imaging Unit Sensor Board. Disconnect CTG0. Is there +24 volts at CTG0-9? Replace the Imaging Unit Sensor Board. Go to Step 7. 7 Check continuity of the CTG0 Harness. Is the wiring harness conductive? Replace the Engine Control Board Replace the harness.