Code: U11
Description: Imaging Unit Fan Failure
Causes: • Imaging Unit Fan, PL6.1.23 • IDFAN Harness, PL5.1.31 • GTG0 Harness, PL5.1.32
Remedy: 1 Test the Imaging Unit Fan. Run the Service Diagnostics Imaging Unit Fan test. Does the Fan operate correctly. Replace the Engine Control Board. Go to Step 2. 2 Check the Fan connection. Is P/J100 securely connected? Replace the Fan. If the error persists, go to Step 3. Connect the Fan. 3 Check for +24 V at the Fan. Disconnect P/J100. Is there +24 V between J100-1 <=> ground? Go to Step 4. Go to Step 5. 4 Check continuity of the IDFAN Harness. Is the wiring harness conductive? Go to Step 5. Replace the harness. 5 Check for +24 V at the Imaging Unit Sensor Board. Disconnect CTG0. Is there +24 V at CTG0-9? Replace the Imaging Unit Sensor Board. Go to Step 6. 6 Check continuity of the CTG0 Harness. Is the wiring harness conductive? Replace the Engine Control Board Replace the harness.