Code: -02
Description: Black Imaging Unit Motor Failure
Causes: • Imaging Unit Motor • Engine Control Interface Board • Engine Control Board
Remedy: 1 Run the Black Imaging Unit Motor test from diagnostics. Does the motor operate correctly? Go to step 7. Go to step 2. 2 Is the voltage at J235-4 +5 VDC? Go to step 3. Use wirenet 8.2 to troubleshoot the missing +5 VDC. 3 Is the voltage at J235-1 +24 VDC? Go to step 4. Use wirenet 8.2 to troubleshoot the missing +24 VDC. 4 Run the Black Imaging Unit Motor test from diagnostics. Is the voltage at J235-5 0 VDC with the test running? Go to step 5. Use wirenet 8.2 to troubleshoot. 5 Is the frequency at J235-8 between 1KHz and 1.3 KHz? Replace the black imaging unit motor. Go to step 6. 6 Is the frequency between J534A-2 and ground between 1 KHz and 1.3 KHz? Check for an open circuit between J534A-8 and J235-8. Replace in order until resolved: • engine interface board • engine control board. 7 Is +3.3 VDC present at J534A-7 with the Motor test running from diagnostics? If there is no mechanical bind in the black imaging unit, replace the black drum drive motor. Use wirenet 8.2 to troubleshoot the missing +3.3 VDC.