Mã lỗi 113 — Xerox Phaser 7750

Code: 113

Description: Finisher Stapler Failure, Code 113 The staple home sensor doesn’t turn ON within 2 seconds after the stapler motor started to turn backwards.
Causes: • Finisher Control Board • Staple Unit Assembly
Remedy: 1 1. Enter service diagnostics. 2. Run the Stapler Home sensor test. 3. Does the value change from H to L when the stapler is moved away from the home position? Go to step 6. Go to step 2. 2 1. Measure the voltage between finisher board connector P852-2 and frame ground. 2. Does the voltage change between 0 and +5 VDC when the sensor is blocked and unblocked? Replace the finisher control board. Go to step 3. 3 1. Measure the voltage at the Finisher Board connector P852-1. 2. Dose the voltage measure +5 VDC? The home sensor or the wiring is bad. Replace the staple unit assembly. Go to step 4. 4 1. Disconnect the Stapler Unit Assembly. 2. Measure the voltage between the finisher board connector P852-1 and frame ground. 3. Does the voltage measure +5 VDC? Replace the stapler unit assembly. Go to step 5. 5 Is +24 VDC present at either J847-7 or J847-9? Replace the finisher control board. Troubleshoot and repair the +24 VDC interlock circuit. 6 1. Enter service diagnostics and run the “Stapler Close Motor” test. 2. Does the stapler motor operate correctly? Replace the finisher control board. Go to step 7. 7 With the Stapler Close Motor test running is +24 VDC present at J847-7? Replace in the following order: • stapler head assembly • finisher control board Troubleshoot and repair the +24 VDC interlock circuit.

← Xem tất cả mã lỗi Xerox Phaser 7750

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie