Code: 113
Description: Finisher Stapler Failure, Code 113 The staple home sensor doesn’t turn ON within 2 seconds after the stapler motor started to turn backwards.
Causes: • Finisher Control Board • Staple Unit Assembly
Remedy: 1 1. Enter service diagnostics. 2. Run the Stapler Home sensor test. 3. Does the value change from H to L when the stapler is moved away from the home position? Go to step 6. Go to step 2. 2 1. Measure the voltage between finisher board connector P852-2 and frame ground. 2. Does the voltage change between 0 and +5 VDC when the sensor is blocked and unblocked? Replace the finisher control board. Go to step 3. 3 1. Measure the voltage at the Finisher Board connector P852-1. 2. Dose the voltage measure +5 VDC? The home sensor or the wiring is bad. Replace the staple unit assembly. Go to step 4. 4 1. Disconnect the Stapler Unit Assembly. 2. Measure the voltage between the finisher board connector P852-1 and frame ground. 3. Does the voltage measure +5 VDC? Replace the stapler unit assembly. Go to step 5. 5 Is +24 VDC present at either J847-7 or J847-9? Replace the finisher control board. Troubleshoot and repair the +24 VDC interlock circuit. 6 1. Enter service diagnostics and run the “Stapler Close Motor” test. 2. Does the stapler motor operate correctly? Replace the finisher control board. Go to step 7. 7 With the Stapler Close Motor test running is +24 VDC present at J847-7? Replace in the following order: • stapler head assembly • finisher control board Troubleshoot and repair the +24 VDC interlock circuit.