Code: 116
Description: Finisher Stacker Height Sensor Off Failure, Code 116 The Stack Height Sensor did not detect that the tray went down within 5 seconds after the Stacker Tray had been signaled to lower down at initialization. Or, the Stack Height Sensor did not detect the tray moving up within 5 seconds after the Stacker Tray had been signaled to lift.
Causes: • Stacker Height Sensor/Actuator • Finisher Control Board
Remedy: 1 1. Actuate the stacker height sensor in diagnostics. 2. Does the value change between H and L? Go to step 2. Troubleshoot using the transmissive sensor procedure. 2 1. Run the Finisher Stacker Motor Down test in diagnostics. 2. Does the stacker tray lower? Go to step 5. Go to step 3. 3 Does the stacker motor turn? Diagnose and repair the mechanical problem. Check the stacker motor gear, stacker tray, and belt track gear. Go to step 4. 4 Is +24 VDC present at P/J 847-12 with the Finisher Stacker Motor Down test running in diagnostics? Replace the stacker motor. Replace the finisher control board. 5 1. Run the Finisher Stacker Motor Up test in diagnostics. 2. Does the stacker tray move up? Replace the finisher control board. Go to step 6. 6 Does the sacker motor turn? Diagnose and repair the mechanical problem. Check the stacker motor gear, stacker tray, and belt track gear. Go to step 7. 7 Is +24 VDC present at P/J 847-11 with the Finisher Stacker Motor Down test running in diagnostics? Replace the stacker motor. Replace the finisher control board.