Mã lỗi 117 — Xerox Phaser 7750

Code: 117

Description: Finisher Stacker Tray Failure, Code 117 The system detected that the Stacker Tray Upper Limit Sensor was turned ON after the Stacker Tray began lifting up. Or the Stacker Tray Upper Limit Sensor remained on after the lowering down of the Stacker Tray was completed.
Causes: • Stacker Motor • Finisher Control Board
Remedy: 1 1. Actuate the stacker upper limit sensor in diagnostics. 2. Does the value change between H and L? Go to step 2. Troubleshoot using the transmissive sensor procedure. 2 1. Run the Finisher Stacker Motor Down test in diagnostics. 2. Does the stacker tray lower? Go to step 5. Go to step 3. 3 Does the stacker motor turn? Diagnose and repair the mechanical problem. Check the stacker motor gear, stacker tray, and belt track gear. Go to step 4. 4 Is +24 VDC present at P/J 847-12 with the Finisher Stacker Motor Down test running in diagnostics? Replace the stacker motor. Replace the finisher control board. 5 1. Run the Finisher Stacker Motor Up test in diagnostics. 2. Does the stacker tray move up? Replace the finisher control board. Go to step 6. 6 Does the stacker motor turn? Diagnose and repair the mechanical problem. Check the stacker motor gear, stacker tray and belt track gear. Go to step 7. 7 Is +24 VDC present at P/J 847-11 with the Finisher Stacker Motor Down test running in diagnostics? Replace the stacker motor. Replace the finisher control board.

← Xem tất cả mã lỗi Xerox Phaser 7750

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie