Code: 118, 119
Description: Finisher Stapler Front Corner On Failure, Code 118 Finisher Stapler Front Corner Off Failure, Code 119 Error Code 118: The Staple Front Corner Sensor did not turn ON within 2 seconds after the system started to move to the Front Corner. Or the Staple Front Corner Sensor remained ON when starting the move to the Front Corner. Error Code 119: The Staple Front Corner Sensor did not turn OFF within 2 seconds after starting to move from the Front Corner. Or the Staple Front Corner Sensor does not turn OFF after the move from the Front Corner was completed.
Causes: • Finisher Control Board • Staple Move Motor
Remedy: 1 1. Manually move the staple head. 2. Does the head move smoothly from front to rear? Go to step 2. Diagnose and repair the mechanical defect. 2 1. Check the Stapler Front Corner Sensor in diagnostics. 2. Does the value change from L to H? Go to step 5. Use the transmissive Sensor procedure to diagnose and repair the sensor. 3 1. Defeat the front door interlock switch then run the Stapler: Move Front or Move Rear motor test in diagnostics. 2. Does the stapler move motor run? Replace the finisher control board. Go to step 4. 4 Is +24 VDC present at P847-4? Replace the stapler move motor. Go to step 5. 5 Is +24 VDC present at test point 9 on the finisher control board? Replace the finisher control board. Troubleshoot and repair the +24 VDC interlock circuit.