Code: 122
Description: Finisher Decurler Failure, Code 122 The level of the Decurler Cam Home Sensor did not change 4 seconds after the Decurler Cam Clutch has turned on.
Causes: • Decurler Cam Clutch • Stacker Motor • Finisher Control Board
Remedy: 1 1. Rotate the actuator while running the Decurler Cam Position test in diagnostics. 2. Does the value change between H and L? Go to step 2. Troubleshoot using the transmissive sensor procedure. 2 Does the decurler cam clutch operate in diagnostics? Check for a mechanical problem with the decurler cam clutch drive. If no problem is found replace the clutch. Go to step 3. 3 Is +24 VDC present at P/J 849-1? Replace the decurler cam clutch. Go to step 4. 4 Is +24 VDC present at test point 5 on the finisher control board? Replace the finisher control board. Troubleshoot the +24 VDC interlock circuit. 5 Is +24 VDC present at P/J 847-11 with the Finisher Stacker Motor Down test running in diagnostics? Replace the stacker motor. Replace the finisher control board