Code: 123
Description: Finisher Set Clamp Failure, Code 123 The set clamp home sensor did not turn on within 2 seconds after the set clamp started operation.
Causes: • Set Clamp Solenoid • Finisher Control Board
Remedy: 1 1. Check the Set Clamp home sensor in diagnostics. 2. Does the value change from H to L while rotating the actuator? Go to step 2. Use the transmissive Sensor procedure to diagnose and repair the sensor. 2 Does the solenoid energize when running the Set Clamp Paddle test in diagnostics? Go to step 3. Go to step 4. 3 1. Run the Eject Forward Test and then the Eject Release Test in diagnostics. 2. Does the set clamp paddle turn once? Replace the finisher control board. Go to step 4. 4 Is +24 VDC present at P848A-10? Go to step 5. Go to step 6. 5 Is +24 VDC present at P848A-11? Replace the finisher control board. Replace the set clamp solenoid. 6 Is +24 VDC present at test point 9 on the finisher control board? Replace the finisher control board. Troubleshoot and repair the +24 VDC interlock circuit.