Mã lỗi 35 — Xerox Phaser 7750

Code: 35

Description: Fuser Main Lamp Failure, Code 35 The lamp control circuit has failed resulting in the front thermistor detecting an overheat condition. Note If this failure reoccurs three times successively, an Engine NVRAM value is set preventing further printer use until the Clear Tech Rep Fault is performed.
Causes: • Fuser • Engine Control Board
Remedy: 1 1. Turn OFF power and remove the fuser assembly and allow it to cool down. 2. Measure the resistance between the Fuser connector P600-4 and P600-6. 3. Does the resistance measure between 30 K and 190 K Ohms? Go to step 2. Replace the fuser assembly. 2 1. Reinstall the fuser assembly. 2. Enter service diagnostics. 3. From the Sensor Tests run the Fuser Temperature test. 4. Is the temperature indicated approximately 165o C? Go to step 4. Go to step 3. 3 1. Turn OFF printer power. 2. Measure the resistance between J641- 2 and J641-3 on the Engine Control Board. 3. Does the resistance measure between 30 K and 190 K Ohms? Go to step 4. Repair or replace the wiring harness. 4 1. Turn printer power back ON. 2. Is there ~+3.4 VDC between J590-5 and ground? Check the AC wiring harness to the fuser. If the check is OK, replace the AC drive assembly. Replace the engine control board.