Code: 41
Description: Install or Reseat Fuser, Code 41 Front thermistor open error. This is a cold condition. Note If this failure reoccurs three times successively, an Engine NVRAM value is set preventing further printer use until the Clear Tech Rep Fault is performed.
Causes: • Fuser • Engine Control Board
Remedy: 1 1. Turn OFF power and remove the Fuser Assembly. 2. Measure the resistance between the fuser connector P600-4 and P600-6. 3. Does the resistance measure between 30 K and 190 K Ohms? Go to step 2. Replace the fuser assembly. 2 1. Reinstall the fuser assembly. 2. Enter service diagnostics. 3. From the Sensor Tests run the Fuser Temperature test. 4. Is the temperature indicated approximately 165o C? Replace the engine control board. Go to step 3. 3 1. Turn OFF printer power. 2. Check for an open circuit or poor connection between J600-4 to J600-6 to J404A-2. 3. Is the wiring OK? Replace the engine control board. Repair or replace the wiring harness.