Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi 48 — Xerox Phaser 7750

Code: 48

Description: Fan Failure, Code 48 The machine logic detected a failure of the Fuser fan, LVPS fan, or rear fan.
Causes: • Fuser Fan • LVPS Fan • Rear Fan
Remedy: 1 1. Enter service diagnostics and run the fan test. 2. Does the fuser fan rotate at a high speed? Go to step 4. Go to step 2. 2 1. Check for voltage at J222-4. 2. Does the voltage measure +24 VDC? Go to step 3. Check the wiring to the fuser fan, if the wiring is OK, replace the engine control board. 3 Does the front panel indicate the fans are ON? Replace the fan. Check the wiring to the fuser fan, if the wiring is OK, replace the engine control board. 4 Does the rear fan revolve at high speed? Go to step 7. Go to step 5. 5 1. Check for voltage at J552-1. 2. Does the voltage measure +24 VDC? Go to step 6. Check the wiring to the rear fan, if the wiring is OK replace the interface board. If the problem continues, replace the engine control board. 6 Does the front panel indicate the fans are ON? Replace the rear fan. Check the wiring tot he rear fan, if the wiring is OK, replace the engine control board. 7 Does the LVPS fan revolve at high speed? The fans are operating correctly. If the problem persists, replace the engine control board. Go to step 8. 8 1. Check for voltage at J214-4. 2. Is +24 VDC present? Go to step 9. Check the wiring to the LVPS fan, if the wiring is OK, replace the engine control board. 9 Does the front panel indicate the fans are ON? Replace the LVPS assembly. Check the wiring to the LVPS fan, if the wiring is OK, replace the engine control board.

← Xem tất cả mã lỗi Xerox Phaser 7750

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie