Mã lỗi 60 — Xerox Phaser 7750

Code: 60

Description: Imaging Unit Motor Failure, Code 60
Causes: • Imaging Unit Drive Motor • Engine Control Board
Remedy: 1 1. Enter service diagnostics and run the Imaging Unit Motor test. 2. Does the motor operate correctly? Go to step 7. Go to step 2. 2 1. Is the voltage at J210-5 +5 VDC? Go to step 3. Replace the engine control board. 3 1. Is the voltage at J210-7 +24 VDC? Go to step 4. Use the +24 VDC wirenets to troubleshoot and resolve the missing voltage. 4 1. Enter service diagnostics. 2. While running the Imaging Unit Motor test, check the voltage at J210-1 and J210-2. 3. Is the voltage 0 VDC while the test is running? Go to step 5. Replace the engine control board. 5 Is the frequency between J210-4 and ground between 1 KHz and 1.3 KHz? Replace the imaging unit drive motor. Go to step 6. 6 1. Check for a short to ground at J210-4. 2. Is the wire grounded? Repair or replace the wiring harness. Replace the engine control board. 7 1. Enter service diagnostics. 2. While running the Imaging Unit Motor test, check the voltage at J210-9. 3. Is the voltage +5 VDC while the test is running? Replace the imaging unit drive motor. Replace the engine control board.

← Xem tất cả mã lỗi Xerox Phaser 7750