Description: Imaging Unit Motor Fail Imaging Unit Motor has failed.
Remedy: 1 1. Enter Service Diagnostics Menu: Printer Menu > Troubleshooting > Service Tools > Printer Status Page > hold the Up and Down buttons simultaneously > Run Service Diagnostics > OK. Perform the Imaging Unit Motor test. 2. Does the Motor operate correctly? Go to step 7. Go to step 2. 2 Is the voltage at J535-5 +5 VDC? Go to step 3. Replace the I/F PWB. 3 Is the voltage at J535-10 +24 VDC? Go to step 4. Replace the I/F PWB. 4 1. Enter Service Diagnostics Menu. 2. While running the Imaging Unit Motor test, check the voltage at J535-1 and J535-2. 3. Is the voltage 0 VDC while the test is running? Go to step 5. Replace the I/F PWB. 5 Is the frequency between J535-4 and ground between 1 KHz and 1.3 KHz? Replace the Imaging Unit Drive Motor. Go to step 6. 6 1. Check for a short to ground at J535-4. 2. Is the wire grounded? Repair or replace the wiring harness. Replace the I/F PWB. 7 1. Enter Service Diagnostics Menu. 2. While running the Imaging Unit Motor test, check the voltage at J535-7. 3. Is the voltage +5 VDC while the test is running? Replace the Imaging Unit Drive Motor. Replace the I/F PWB.