Description: Zero Crossing Signal Not Detected The zero crossing signal is not detected.
Remedy: Check that J590 on the AC Drive PWB (PL 9.2) is securely connected. Check that J412 on the Engine Control Board (MCU PWB) (PL 13.1) is securely connected. Check the condition of the wires between J590 and J412. The connections and wires are good. Y↓N→Repair as required. Measure the voltage at 590-1 on the AC Drive PWB (pin 1 is toward inside of machine). Check for both DC and AC voltages of 0.44 VDC and 0.92 VAC. The voltage measures approximately 0.5 VDC and 1 VAC. Y↓N→Measure the voltage at J590-7 (pin 1 is toward inside of machine) for +5 VDC. The voltage measures +5 VDC. Y↓N→The wires were previously checked. Replace the Engine Control Board) (MCU PWB (PL 13.1). Measure the voltage at J590-5 (pin 1 is toward inside of machine) for less than +1 VDC. The voltage measures less than 1 VDC. Y↓N→The wires were previously checked. Replace the Engine Control Board (MCU PWB) (PL 13.1). Replace the AC Drive PWB (PL 9.2). Measure the voltage at J412-19 on the Engine Control Board (MCU PWB). The voltage measures less than 1 VDC. Y↓N→Repair the open circuit between J590-1 on the AC Drive PWB and J412-19 on the Control Board (MCU PWB). Replace the Engine Control Board (MCU PWB) (PL 13.1).