Description: Waste Cartridge Full Toner Sensor Fail The Full Toner Sensor detects a full toner condition.
Remedy: 1 1. Remove the Waste Cartridge Sensor Holder without disconnecting the harnesses. 2. Measure the voltage between the Yellow wire on the Waste Cartridge Full Sensor and frame ground, alternately interrupting the sensor. 3. Does the voltage toggle between +5 and 0 VDC? Go to step 5. Go to step 2. 2 1. Measure the voltage between the gray wire and frame ground. 2. Does the voltage measure +5 VDC? Go to step 4. Go to step 3. 3 1. Remove the Rear Cover. 2. Measure the voltage at J404B-15 on the Engine Control Board. 3. Does the voltage measure +5 VDC? Inspect the wiring harness for damage and replace, if necessary. Replace the Engine Control Board (MCU PWB). 4 1. Measure the voltage between the violet wire and frame ground. 2. Does the voltage measure 0 VDC? Replace the Waste Cartridge Full Sensor. Inspect the wiring harness for damage and replace, if necessary. 5 1. Remove the Rear Cover. 2. Measure the voltage at J404B-14 on the Engine Control Board. 3. Alternately interrupt the Sensor. 4. Does the voltage measure between +5 and 0 VDC? Replace the Engine Control Board (MCU PWB). Inspect the wiring harness for damage and replace, if necessary.