Description: Yellow Toner Cartridge Near Empty The Yellow Toner Cartridge is nearly empty/empty. This fault requires service only if the message appears before the Toner Cartridge is depleted. NOTE: Continuous running of high density prints can temporarily deplete the toner supply.
Remedy: Enter Service Diagnostics Menu: Printer Menu > Troubleshooting > Service Tools > Printer Status Page > hold the Up and Down buttons simultaneously > Run Service Diagnostics > OK. Run the Yellow Dispenser Motors test. The Yellow Toner Dispense Motor (PL 6.1) energizes. Y↓N→ There is +24 VDC from J406-3 to GND. Y↓N→Go to the +24 VDC Wirenets ( Wiring Data, +24 VDC Wirenets ) and troubleshoot the problem. There is +24 VDC from J406-2 to GND. Y↓N→Check the wires from J406 to J227 for an open circuit. If the wires are OK, replace the Yellow Toner Dispense Motor (PL 6.1). Perform Service Diagnostics. The voltage from J406-2 to GND drops to less than 1 VDC. Y↓N→Replace the MCU PWB (PL 13.1). If the problem continues, replace the I/F PWB (PL 9.1). Check the wires from J406 to J227 for an open circuit. If the wires are OK, replace the Yellow Toner Dispense Motor (PL 6.1). Run the Developer Motors test. The Developer Motor energizes (PL 1.1). Y↓N→ There is +24 VDC from J535-3 to J535-4 on the I/F PWB. Y↓N→Go to the +24 VDC Wirenets ( Wiring Data, +24VDC ) and troubleshoot the problem. There is +5 VDC from J535-7 to J535-6 on the I/F PWB. Y↓N→Refer to the +5 VDC Wirenets ( Wiring Data, +5.5 VDC Wirenet ) and troubleshoot the problem. Check the wires between J533 and J535 on the I/F PWB and J232 at the Developer Motor for open or short circuit failures or loose connections. If the wires are OK, replace the Developer Motor (PL 1.1). If the problem continues, replace the MCU PWB (PL 13.1). Perform TRC Adjustment ADJ 9.3. The Yellow ATC Sensor check is OK. Y↓N→Go to the 009-380, 009-381, 009-382, 009-383, ATC Sensor Failure RAP. After checking that no failures are detected during normal operation, go to call closeout.