Description: ADC Sensor Fail The control logic detected an ADC Sensor operation failure.
Remedy: Perform the ADC Output Check, ADJ 9.4 (). The check of the ADC Sensor is OK. Y↓N→There is +5 VDC from J404B-8 on the MCU PWB to GND. Y↓N→Check the wires and connectors. If the check is OK, replace the Engine Control Board (MCU PWB) (PL 13.1). Enter Service Diagnostics Menu: Printer Menu > Troubleshooting > Service Tools > Printer Status Page > hold the Up and Down buttons simultaneously > Run Service Diagnostics > OK. Perform the ADC Sensor test. The ADC Shutter Solenoid energized (PL 1.3). Y↓N→Check the wires and connectors. If the check is OK, replace the Engine Control Board (MCU PWB) (PL 13.1). There is 0 VDC from J404B-3 on the I/F PWB to GND. Y↓N→Check the wires and connectors. If the check is OK, replace the MCU PWB (PL 13.1). The voltage from J404B-1 to GND changed to 0VDC momentarily. Y↓N→Check the wires and connectors. If the check is OK, replace the MCU PWB (PL 13.1). Check the wires and connectors. If the check is OK, replace the, replace the ADC Sensor Assembly (PL 1.3). After checking that no failures are detected during normal operation, go to call closeout.