Mã lỗi 009-684 — Xerox Phaser 7760

Code: 009-684

Description: ADC Shutter Fail The control logic detected an ADC Shutter operation failure.
Remedy: Enter Service Diagnostics Menu: Printer Menu > Troubleshooting > Service Tools > Printer Status Page > hold the Up and Down buttons simultaneously > Run Service Diagnostics > OK. Perform the ADC Solenoid tests. The ADC Shutter Solenoid energized. Y↓N→There is +24 VDC from J404B-2 on the MCU PWB to GND. Y↓N→Check the wires and connectors. If the check is OK, replace the I/F PWB (PL 9.1). If the problem continues, replace the ADC Sensor (PL 1.3). There is 0 VDC from J404B-3 on the MCU PWB to GND. Y↓N→Check the wires and connectors. If the check is OK, replace the I/F PWB (PL 9.1). If the problem continues, replace the MCU PWB (PL 13.1). If the problem continues, replace the ADC Sensor (PL 1.3). The voltage from J404B-1 on the MCU PWB to GND changed to 0VDC momentarily. Y↓N→Check the wires and connectors. If the check is OK, replace the I/F PWB (PL 9.1). If the problem continues, replace the Engine Control Board (MCU PWB) (PL 13.1). If the problem continues, replace the ADC Sensor (PL 1.3). Check the wires and connectors. If the check is OK, replace the ADC Sensor (PL 1.3). After checking that no failures are detected during normal operation, go to call closeout.