Description: Bottom, Developer Fan Fail The machine logic detected a failure of the Bottom Fan or the Developer Fan.
Remedy: Enter Service Diagnostics Menu: Printer Menu > Troubleshooting > Service Tools > Printer Status Page > hold the Up and Down buttons simultaneously > Run Service Diagnostics > OK. Run the Fan Motors test. The Developer Fan (PL 9.1) revolves at high speed. Y↓N→There is +24 VDC from J404A pin 1 to frame gnd. Y↓N→Check the wires and connectors to the Developer Fan. If the check is OK, replace the Engine Control Board (MCU PWB) (PL 13.1). If the problem continues replace the I/F PWB (PL 9.1). Check the wires and connectors to the Developer Fan. If the check is OK, replace the Developer Fan (PL 9.1). The Bottom Fan (PL 8.1) revolves at high speed. Y↓N→There is +24 VDC from J534 pin 1 to frame gnd. Y↓N→Check the wires and connectors to the Bottom Fan. If the check is OK, replace the Engine Control Board (MCU PWB) (PL 13.1). Check the wires and connectors to the Bottom Fan. If the check is OK, replace the Bottom Fan (PL 8.1). Perform Service Diagnostics. The display is L. Y↓N→Check the fan failure wires and connectors for an open circuit. If the check is OK, replace the fans, one at a time. If this does not resolve the problem, replace the Engine Control Board (MCU PWB) (PL 13.1). The Fans are operating correctly. If the problem continues replace the Engine Control Board (MCU PWB) (PL 13.1).