Code: 012-227
Description: Booklet End Guide Home Sensor Off Fail Even when Booklet End Guide motor outputs 200 pulse after the start, Booklet End Guide Home Sensor is not turned Off.
Remedy: • Check the Booklet End Guide Home Sensor for improper installation. • Check the Booklet End Guide Home Sensor connectors for connection failure. • Check the Booklet End Guide Motor connectors for connection failure. • Check the Guide for deformation. • Check the Guide for a foreign substance.
Enter Service Diagnostics Menu: Printer Menu > Troubleshooting > Service Tools > Printer Status Page > hold the Up and Down buttons simultaneously > Run Service Diagnostics > OK. Perform the Booklet End Guide Motor test. The Booklet End Guide Motor (PL 21.17) energizes. Y↓N→Check continuity between the Booklet End Guide Motor and the Booklet PWB and the Booklet PWB and the Finisher PWB. The continuity check is OK. Y↓N→Repair the open circuit or short circuit. Replace the Booklet End Guide Motor (PL 21.17). If the problem continues, replace the Booklet PWB (PL 21.12). If the problem persists, replace Finisher PWB (PL 21.12). Block/unblock the Booklet End Guide Home Sensor to the light with paper strip. The display changes. Y↓N→Check continuity between the Booklet End Guide Home Sensor and the Booklet PWB and the Booklet PWB and the Finisher PWB. The continuity check is OK. Y↓N→Repair the open circuit or short circuit. Replace the Booklet End Guide Home Sensor (PL 21.17). If the problem continues, replace the Booklet PWB (PL 21.12). If the problem persists, replace Finisher PWB (PL 21.12). Check the following: • The Booklet End Guide Motor for proper installation • Booklet End Guide Belt for proper tension • Booklet End Guide Belt for wear or damage If the above checks are OK, replace the Finisher PWB (PL 21.12).
Enter Service Diagnostics Menu: Printer Menu > Troubleshooting > Service Tools > Printer Status Page > hold the Up and Down buttons simultaneously > Run Service Diagnostics > OK. Perform the Booklet End Guide Motor test. The Booklet End Guide Motor (PL 21.17) energizes. Y↓N→Check continuity between the Booklet End Guide Motor and the Booklet PWB and the Booklet PWB and the Finisher PWB. The continuity check is OK. Y↓N→Repair the open circuit or short circuit. Replace the Booklet End Guide Motor (PL 21.17). If the problem continues, replace the Booklet PWB (PL 21.12). If the problem persists, replace Finisher PWB (PL 21.12). Block/unblock the Booklet End Guide Home Sensor to the light with paper strip. The display changes. Y↓N→Check continuity between the Booklet End Guide Home Sensor and the Booklet PWB and the Booklet PWB and the Finisher PWB. The continuity check is OK. Y↓N→Repair the open circuit or short circuit. Replace the Booklet End Guide Home Sensor (PL 21.17). If the problem continues, replace the Booklet PWB (PL 21.12). If the problem persists, replace Finisher PWB (PL 21.12). Check the following: • The Booklet End Guide Motor for proper installation • Booklet End Guide Belt for proper tension • Booklet End Guide Belt for wear or damage If the above checks are OK, replace the Finisher PWB (PL 21.12).