Code: 012-247
Description: Side Regi Sensor Off Fail Side Regi Sensor not turned Off after the lapse of 500msec from operation start. Side Regi Sensor is not turned Off after the stop following Side Regi Sensor Off. Target Side Regi Sensor1 or Side Regi Sensor2 is not turned Off at operation start.
Remedy: • Check the Actuator for deformation. • Check the Side Reg 1 and 2 Sensors for improper installation. • Check the Side Reg 1 and 2 Sensors connectors for connection failure. • Check the Puncher Move Motor connectors for connection failure.
Enter Service Diagnostics Menu: Printer Menu > Troubleshooting > Service Tools > Printer Status Page > hold the Up and Down buttons simultaneously > Run Service Diagnostics > OK. Run the Puncher Move Motor test. The Puncher Move Motor (PL 21.5) runs. Y↓N→Check continuity between the Puncher Move Motor and Finisher PWB. The continuity check is OK. Y↓N→Repair the open circuit or short circuit. Replace the Puncher Move Motor (PL 21.5). If the problem continues, replace the Finisher PWB (PL 21.12). Block/unblock the Side Reg 1 Sensor (PL 21.5). The display changes. Y↓N→Check continuity between the Side Reg 1 Sensor and Finisher Main PWB. The continuity check is OK. Y↓N→Repair the open circuit or short circuit. Replace the Side Reg 1 Sensor (PL 21.5). If the problem continues, replace the Finisher PWB (PL 21.12). Block/unblock the Side Reg 2 Sensor (PL 21.5). The display changes. Y↓N→Check continuity between the Side Reg 2 Sensor and Finisher PWB. The continuity check is OK. Y↓N→Repair the open circuit or short circuit. Replace the Side Reg 2 Sensor (PL 21.5). If the problem continues, replace the Finisher PWB (PL 21.12). Check the following: • The Puncher Move Motor Belt for improper tension • The Puncher Move Motor Belt for disengagement If the above checks are OK, replace the Finisher PWB (PL 21.12).
Enter Service Diagnostics Menu: Printer Menu > Troubleshooting > Service Tools > Printer Status Page > hold the Up and Down buttons simultaneously > Run Service Diagnostics > OK. Run the Puncher Move Motor test. The Puncher Move Motor (PL 21.5) runs. Y↓N→Check continuity between the Puncher Move Motor and Finisher PWB. The continuity check is OK. Y↓N→Repair the open circuit or short circuit. Replace the Puncher Move Motor (PL 21.5). If the problem continues, replace the Finisher PWB (PL 21.12). Block/unblock the Side Reg 1 Sensor (PL 21.5). The display changes. Y↓N→Check continuity between the Side Reg 1 Sensor and Finisher Main PWB. The continuity check is OK. Y↓N→Repair the open circuit or short circuit. Replace the Side Reg 1 Sensor (PL 21.5). If the problem continues, replace the Finisher PWB (PL 21.12). Block/unblock the Side Reg 2 Sensor (PL 21.5). The display changes. Y↓N→Check continuity between the Side Reg 2 Sensor and Finisher PWB. The continuity check is OK. Y↓N→Repair the open circuit or short circuit. Replace the Side Reg 2 Sensor (PL 21.5). If the problem continues, replace the Finisher PWB (PL 21.12). Check the following: • The Puncher Move Motor Belt for improper tension • The Puncher Move Motor Belt for disengagement If the above checks are OK, replace the Finisher PWB (PL 21.12).