Description: Clamp Home Sensor On Fail Set Clamp Home Sensor is not turned On within a specified time.
Remedy: 1 1. Enter Service Diagnostics Menu: Printer Menu > Troubleshooting > Service Tools > Printer Status Page > hold the Up and Down buttons simultaneously > Run Service Diagnostics > OK. Check the Set Clamp Home Sensor: Finisher Tests > Finisher Sensors > Misc. 2. Does the value change from H to L while rotating the actuator? To to step 2. Use the Transmissive Sensor Procedure () to diagnose and repair the Sensor. 2 Does the Solenoid energize when running the Set Clamp Paddle test in Diagnostics? Go to step 3. Go to step 4. 3 1. Perform the Eject Forward test and then the Eject Release test in Diagnostics. 2. Does the Set Clamp Paddle turn once? Replace the Finisher Control Board. Go to step 4. 4 Is +24 VDC present at P848A-10? Go to step 5. Go to step 6. 5 Is +24 VDC present at 848A-11? Replace the Finisher Control Board. Replace the Set Clamp Solenoid. 6 Is +24 VDC present at test point 9 on the Finisher Control Board? Replace the Finisher Control Board. Troubleshoot and repair the +24 VDC Interlock circuit.