Mã lỗi 012-291 — Xerox Phaser 7760

Code: 012-291

Description: Stapler Fail The Stapler Home Sensor does not turn On within 2 seconds after the Stapler Motor started to turn backwards.
Remedy: 1 1. Enter Service Diagnostics Menu: Printer Menu > Troubleshooting > Service Tools > Printer Status Page > hold the Up and Down buttons simultaneously > Run Service Diagnostics > OK. 2. Perform the Stapler Home Sensor test. 3. Does the value change from H to L when the Stapler is moved away from the Home position? To to step 6. Go to step 2. 2 1. Measure the voltage between the Finisher PWB connector P852-2 and Frame ground. 2. Does the voltage change between 0 and +5 VDC when the Sensor is blocked and unblocked Replace the Finisher PWB. Go to step 3. 3 1. Measure the voltage at the Finisher Board connector P852-1. 2. Does the voltage measure +5 VDC? The Home Sensor or the wiring is bad. Replace the Staple Assembly. Go to step 4. 4 1. Disconnect the Stapler Unit Assembly. 2. Measure the voltage between the Finisher PWB connector P852-1 and Frame ground. 3. Does the voltage measure +5 VDC? Replace the Stapler Assembly. Go to step 5. 5 Is +24 VDC present at P/J847-7 or J847-9? Replace the Finisher PWB. Troubleshoot and repair the +24 VDC Interlock circuit. 6 1. Enter Service Diagnostics Menu. Run the Stapler Close Motor test. 2. Does the Stapler Motor operate correctly? Replace the Finisher Control Board. Go to step 7. 7 With the Stapler Close Motor test running, is +24 VDC present at J847-7? Replace in the following order: 1. Stapler Assembly 2. Finisher PWB Troubleshoot and repair the +24 VDC Interlock circuit.

← Xem tất cả mã lỗi Xerox Phaser 7760

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie