Description: Stapler Fail The Stapler Home Sensor does not turn On within 2 seconds after the Stapler Motor started to turn backwards.
Remedy: 1 1. Enter Service Diagnostics Menu: Printer Menu > Troubleshooting > Service Tools > Printer Status Page > hold the Up and Down buttons simultaneously > Run Service Diagnostics > OK. 2. Perform the Stapler Home Sensor test. 3. Does the value change from H to L when the Stapler is moved away from the Home position? To to step 6. Go to step 2. 2 1. Measure the voltage between the Finisher PWB connector P852-2 and Frame ground. 2. Does the voltage change between 0 and +5 VDC when the Sensor is blocked and unblocked Replace the Finisher PWB. Go to step 3. 3 1. Measure the voltage at the Finisher Board connector P852-1. 2. Does the voltage measure +5 VDC? The Home Sensor or the wiring is bad. Replace the Staple Assembly. Go to step 4. 4 1. Disconnect the Stapler Unit Assembly. 2. Measure the voltage between the Finisher PWB connector P852-1 and Frame ground. 3. Does the voltage measure +5 VDC? Replace the Stapler Assembly. Go to step 5. 5 Is +24 VDC present at P/J847-7 or J847-9? Replace the Finisher PWB. Troubleshoot and repair the +24 VDC Interlock circuit. 6 1. Enter Service Diagnostics Menu. Run the Stapler Close Motor test. 2. Does the Stapler Motor operate correctly? Replace the Finisher Control Board. Go to step 7. 7 With the Stapler Close Motor test running, is +24 VDC present at J847-7? Replace in the following order: 1. Stapler Assembly 2. Finisher PWB Troubleshoot and repair the +24 VDC Interlock circuit.