Description: Stapler Move Position Sensor On Fail The Staple Move Sensor did not turn On within 2 seconds after the system has started to move to the Staple position and the Staple Move Sensor has turned Off, or the Staple Move Sensor did not turn On after the move to the Staple position has completed.
Remedy: 1 1. Manually move the Staple Head. 2. Does the Head move smoothly from front to rear? To to step 2. Diagnose and repair the mechanical defect. 2 1. Enter Service Diagnostics Menu: Printer Menu > Troubleshooting > Service Tools > Printer Status Page > hold the Up and Down buttons simultaneously > Run Service Diagnostics > OK. 2. Perform the Staple Move Sensor test. 3. Does the value change from L to H when the Sensor is blocked? Go to step 3. Refer to Transmissive Sensor Procedure () to diagnose and repair the Sensor. 3 1. Measure the voltage at the Finisher Board connector P852-1. 2. Does the voltage measure +5 VDC? The Home Sensor or the wiring is bad. Replace the Stapler Assembly. Go to step 4. 4 Is +24 VDC present at P847 pins 1, 2, 5, and 6? Replace the following order: 1. Stapler Move Motor 2. Finisher PWB Go to step 5. 5 Is +24 VDC present at P847-4? Replace the Finisher PWB. Troubleshoot the +24 VDC Interlock circuit using 24 VDC Low-Voltage Power Supplies troubleshooting procedure ().