Remedy: There is +24 VDC measured between the Nip/Release Solenoid Pin 1 (+) and GND (-). Y↓N→There is +24 VDC measured between the PWB Pin 5 (+) and GND(-). Y↓N→Check +24 VDC inputs on the PWB. If the check is OK, replace the PWB. Check the wire between the PWB Pin 5 and the Nip/Release Solenoid Pin 1 for an open circuit or poor contact. There is +24 VDC measured between the PWB Pin 4 (+) and GND(-). Y↓N→There is +24 VDC measured between the Nip/Release Solenoid Pin 3 (+) and GND (- ). Y↓N→Replace the Nip/Release Solenoid. Check the wire between the PWB Pin 4 and the Nip/Release Solenoid Pin 3 for an open circuit and poor contact. Follow the following when the release caused a problem. There is +24 VDC measured between the PWB Pin 6 (+) and GND(-). Y↓N→There is +24 VDC measured between the Nip/Release Solenoid Pin 2 (+) and GND (-) Y↓N→Replace the Nip/Release Solenoid. Check the wire between the PWB Pin 6 and the Nip/Release Solenoid Pin 2 for an open circuit or poor contact. Replace the PWB.